Modular Online UPS 50 – 600KW

Nominal Capacity: 50 – 600KW

Nominal Voltage: 380/400/415VAC

Maximum Input Voltage Range: +-20%

Nominal Frequency: 50/60HZ

 

Application field:

Data Center

IDC

ISP

Telecom

Share Product :

Facebook
Pinterest
LinkedIn

Modular Online UPS 50 – 600KW

Main Features:

1.1 Summarization

Our UPS is a kind of three-in- three -out high frequency online UPS, it provides three specifications: The 200~600kVA. The products are modularized and adopt the N+X redundancy. It can flexibly increase the number of the UPS modules according to the load capacity which is convenient for flexible allocation and gradually investment.

The UPS can solve most of the power supply problems, such as blackout, over-voltage, under-voltage, voltage sudden drop, oscillating of decreasing extent, high voltage pulse, voltage fluctuation, surge, inrush current, harmonic distortion (THD), noise interference, frequency fluctuation, etc..

This UPS can be applied to different applications from computer device, automatic equipment, communication system to industry equipment

1.2 Functions and Features

  • Digital control
  • 19-inch standard cabinet

2-meter high cabinets are provided according to the user’s requirement.

  •  Modularized design
  •  High power-density design

The height of the single module is 3U.

  • N+X parallel redundancy

This series UPS adopts N+X parallel redundancy design, user can set different redundancy according to the importance of the load. While the redundancy modules are set more than two, the availability of UPS system will achieve 99.999%, which may satisfy the required reliability of the critical load connected. Through LCD display setting, you may configure the required quantity of the redundancy unit. When the load connected is over the number of the redundancy, the UPS will alert right away. The design of the MTBF (Meantime before Failure) is up to 250,000 hours.

This series can set the number of redundancy modules. When the load exceeds the redundancy setting, the UPS can still work normally and simultaneously send out corresponding warning as long as the load doesn’t exceed the total capacity of modules.

  •  Parallel redundant control system
  •  Optimizing distributed convergence for the cabinet
  •  Centralized bypass
  •  Common Battery
  •  Automatic charge current adjustment according to battery capacity connected.
  •  3-Stage Intelligent charging
  •  Touch-screen Super-large LCD display
  •  Remote monitoring via SNMP
  •  Optional Accessories available such as Isolation transformer, distribution Panel, SNMP Card,

Relay Contact Board, etc…

  •  Equip with Maintenance Bypass Switch for easy maintenance purpose.
  •  Superior MTTR (Meantime to repair) & Short shutdown time in maintenance
  •  Centralized monitoring module is also available
  •  EPO and REPO function

 

1.3 Model description

This document describes the following UPS models:

  • 200kVA
    The models provide 4 configurations: 50 kVA, 100 kVA, 150 kVA and 200 kVA
  • 300kVA
    The models provide 6 configurations: 50 kVA, 100 kVA, 150 kVA, 200 kVA, 250 kVA and 300 kVA.
  • 400kVA
    The models provide 8 configurations: 50 kVA, 100 kVA, 150 kVA, 200 kVA, 250 kVA, 300 kVA, 350 kVA and 400 kVA.
  • 500kVA
    The models provide 10 configurations: 50 kVA, 100 kVA, 150 kVA, 200 kVA, 250 kVA, 300 kVA, 350 kVA, 400 kVA, 450 kVA and 400 kVA.
  • 600kVA
    The models provide 12 configurations: 50 kVA, 100 kVA, 150 kVA, 200 kVA, 250 kVA, 300 kVA, 350 kVA, 400 kVA, 450 kVA, 500 kVA, 550 kVA and 400 kVA.
  • 200kVA supports cable routing from the top and can support cable routing
  • 300kVA supports cable routing from the top and can support cable routing
    from the bottom if a cable entry cabinet is configured.
  • 400kVA standard cabinet supports cable routing from the top.
  • 400kVA full configuration cabinet supports cable routing from the bottom and top.
  • 500kVA supports cable routing from the bottom and top.
  • 600kVA supports cable routing from the bottom and top.
  • Standard configuration : cabinet only with maintenance bypass switch
  • Full configuration : cabinet with mains, bypass, maintenance and output switch

Enquire Now